21,931 research outputs found

    High-temperature oxidation and erosion-resistant refractory coatings

    Get PDF
    Various refractory coating systems were evaluated for rocket nozzle applications by actual rocket test firings. A reference is noted which identifies failure mechanisms and gives results of the firing tests for 18 coating systems. Iridium, iridium-rhenium, and hafnium oxide-zirconium oxide coatings show most promising results

    Cycles of construing in radicalization and deradicalization: a study of Salafist Muslims.

    Get PDF
    © Taylor & Francis Group, LLC.This article explores radicalization and deradicalization by considering the experiences of six young Tunisian people who had become Salafist Muslims. Their responses to narrative interviews and repertory grid technique are considered from a personal construct perspective, revealing processes of construing and reconstruing, as well as relevant aspects of the structure and content of their construct systems. In two cases, their journeys involved not only radicalization but self-deradicalization, and their experiences are drawn on to consider implications for deradicalization.Peer reviewedFinal Accepted Versio

    Failure of non-vacuum steam sterilization processes for dental handpieces

    Get PDF
    Background: Dental handpieces are used in critical and semi-critical operative interventions. Although a number of dental professional bodies recommend that dental handpieces are sterilized between patient use there is a lack of clarity and understanding of the effectiveness of different steam sterilization processes. The internal mechanisms of dental handpieces contain narrow lumens (0·8-2·3mm) which can impede the removal of air and ingress of saturated steam required to achieve sterilization conditions. Aim: To identify the extent of sterilization failure in dental handpieces using a non-vacuum process. Methods: In-vitro and in-vivo investigations were conducted on commonly used UK benchtop steam sterilizers and three different types of dental handpieces. The sterilization process was monitored inside the lumens of dental handpieces using thermometric (TM) methods (dataloggers), chemical indicators (CI) and biological indicators (BI). Findings: All three methods of assessing achievement of sterility within dental handpieces that had been exposed to non-vacuum sterilization conditions demonstrated a significant number of failures (CI=8/3,024(fails/n tests); BI=15/3,024; TM=56/56) compared to vacuum sterilization conditions (CI=2/1,944; BI=0/1,944; TM=0/36). The dental handpiece most likely to fail sterilization in the non-vacuum process was the surgical handpiece. Non-vacuum sterilizers located in general dental practice had a higher rate of sterilization failure (CI=25/1,620; BI=32/1,620; TM=56/56) with no failures in vacuum process. Conclusion: Non-vacuum downward/gravity displacement, type-N steam sterilizers are an unreliable method for sterilization of dental handpieces in general dental practice. The handpiece most likely to fail sterilization is the type most frequently used for surgical interventions

    Investigating steam penetration using thermometric methods in dental handpieces with narrow internal lumens during sterilizing processes with non-vacuum or vacuum processes

    Get PDF
    Background: Dental handpieces are required to be sterilized between patient use. Vacuum steam sterilization processes with fractionated pre/post-vacuum phases or unique cycles for specified medical devices, are required for hollow instruments with internal lumens to assure successful air removal. Entrapped air will compromise achievement of required sterilization conditions. Many countries and professional organisations still advocate non-vacuum sterilization processes for these devices. Aim: To investigate non-vacuum downward/gravity displacement, type-N steam sterilization of dental handpieces, using thermometric methods to measure time to achieve sterilization temperature at different handpiece locations. Methods: Measurements at different positions within air turbines were undertaken with thermocouples and dataloggers. Two examples of commonly used UK benchtop steam sterilizers were tested; a non-vacuum benchtop sterilizer (Little Sister 3, Eschmann, UK) and a vacuum benchtop sterilizer (Lisa, W&H, Austria). Each sterilizer cycle was completed with three handpieces and each cycle in triplicate. Findings: A total of 140 measurements inside dental handpiece lumens were recorded. We demonstrate that the non-vacuum process fails (time range 0-150 seconds) to reliably achieve sterilization temperatures within the time limit specified by the International standard (15 seconds equilibration time). The measurement point at the base of the handpiece failed in all test runs (n=9) to meet the standard. No failures were detected with the vacuum steam sterilization type B process with fractionated pre-vacuum and post-vacuum phases. Conclusion: Non-vacuum downward/gravity displacement, type-N steam sterilization processes are unreliable in achieving sterilization conditions inside dental handpieces and the base of the handpiece is the site most likely to fail

    Operational interpretations of quantum discord

    Get PDF
    Quantum discord quantifies non-classical correlations going beyond the standard classification of quantum states into entangled and unentangled ones. Although it has received considerable attention, it still lacks any precise interpretation in terms of some protocol in which quantum features are relevant. Here we give quantum discord its first operational meaning in terms of entanglement consumption in an extended quantum state merging protocol. We further relate the asymmetry of quantum discord with the performance imbalance in quantum state merging and dense coding.Comment: v4: 5 pages, 1 fig. Refs added, text improved. Main results unchanged. See arXiv:1008.4135v2 for a related work. v5: close to the published versio

    Empowering and assisting natural human mobility: The simbiosis walker

    Get PDF
    This paper presents the complete development of the Simbiosis Smart Walker. The device is equipped with a set of sensor subsystems to acquire user-machine interaction forces and the temporal evolution of user's feet during gait. The authors present an adaptive filtering technique used for the identification and separation of different components found on the human-machine interaction forces. This technique allowed isolating the components related with the navigational commands and developing a Fuzzy logic controller to guide the device. The Smart Walker was clinically validated at the Spinal Cord Injury Hospital of Toledo - Spain, presenting great acceptability by spinal chord injury patients and clinical staf

    SuperSAGE

    Get PDF

    Amplification of surface plasmon polaritons in the presence of nonlinearity and spectral signatures of threshold crossover

    Full text link
    We describe effects of nonlinearity on propagation of surface plasmon polaritons (SPPs) at an interface between a metal and an amplifying medium of the externally pumped two-level atoms. Using Maxwell equations we derive the nonlinear dispersion law and demonstrate that, the nonlinear saturation of the linear gain leads to formation of stationary SPP modes with the intensities independent from the propagation distance. Transition to the regime of stationary propagation is similar to the threshold crossover in lasers and leads to narrowing of the SPP spectrum.Comment: http://www.opticsinfobase.org/ol/abstract.cfm?uri=ol-34-18-286
    corecore